Compact brass 1 1/2 inch industrial combination nozzle has the option of either a fog pattern or a straight stream. This 48 GPM nozzle is well suited for lower pressures but can be used up to 100 PSI.
National Hose (NH) aka National Standard Thread (NST) is often referred to as “fire hose thread” as this is by far the most common thread in use today by fire departments
How we conducted our nozzle testing
We used a Honda self-priming water pump with a two inch inlet and a two inch outlet that produces 135 gallons per minute (GPM). The nozzle was attached to a fifty foot 1 1/2 inch fire hose. The pump pressure was approximately 60 PSI. Gallons per minute was calculated by measuring the number of gallons a nozzle could fill a large container within one minute. The result is the GPM.
WARNING: This product contains a chemical known to the State of California to cause birth defects or other reproductive harm. Do not use in connection with drinking water. Wash hands after handling.