White 1 1/2" x 100' Pin Rack Hose (Brass NH Couplings)

Skip to product information
1 of 4
Regular price Price: $180.69
Regular price $0.00 Sale price $180.69
Sale Sold out

Stock Level: 0

Product Status: Special Order

When Will it Ship: Contact for Lead Time

Shipping Cost: Free Shipping

Shipping Transit Time: 2 to 5 Business Days

Eligible for Express Shipping: No

Stock Level Updated: Dec 5, 2024


Item Number: 15PR5100B
Weight: 14.0 lb
  • Hose Size: 1 1/2 inches (Inside Diameter)
  • Hose Length: 100 feet (Approximately)
  • Male Coupling: Brass 1 1/2 inch NH / NST
  • Swivel Female Coupling: Brass 1 1/2 inch NH / NST
  • The Female Coupling will only Connect to a Male 1 1/2 inch NH / NST
  • Compatible Nozzle: 1 1/2 inch NH / NST only
  • Hose Type: Polyester Single Jacket (Mildew Resistant)
  • Color: White
  • Liner: PU Liner
  • Approximate Width Laying Flat: 2 1/2 inches
  • Service Pressure: 250 PSI
  • Proof Test Pressure: 500 PSI
  • Pre-folded for ease of installation
  • FM Approved Standard
View full details

Collapsible content

Description

1 1/2 inch all polyester single jacket fire hose specifically designed for interior fire fighting use, pin racks, and/or fire cabinets in buildings and plants. NFPA 1961 standards shall be observed in production and assembly to insure quality and durability. Includes hose and couplings only. Rack hose is also known as cabinet hose and reel hose. This product does not include rack or cabinet; includes hose with attached couplings only.

Brass NH couplings are standard (aluminum available). Brass and aluminum female couplings have two rocker lugs. Hose comes pre-folded and is for emergency fire fighting only.

This hose is not for wash-down duties or any other multi-use application; please see our single jacket, double jacket or rubber covered hose for other applications.

Due to dated nature of this hose returns are not accepted on this product.

Applications

  • Interior firefighting
  • Apartment buildings
  • Office buildings
  • Manufacturing Plants

Number of Folds (Approximately)

  • 50’ – 12 folds
  • 75’ - 19 folds
  • 100’ – 25 folds
  • 125’ – 27 folds

Test Ratings (Water Only With Expansion Ring Couplings)

  • Service Pressure (A 3-minute hydrostatic test conducted by users on in-service hose to determine suitability for continued service)
  • Proof Test Pressure (A pressure equal to a least two times the service test pressure)

Specifications

1 1/2" Hose Male Couplings

  • Inside diameter of a male coupling: 1 1/2 inches
  • Outside diameter of a male NH / NST coupling: 2 inches (1.99) - 9 Threads per inch
  • Outside diameter a male NPSH or NPT coupling: 1 7/8 inches (1.87) - 11.5 Threads per inch

Download Spec Sheet

Help Me Connect

NH / NST: The most common thread type in use by fire departments today is NST or National Standard Thread. NST also goes by the initials NH or National Hose. It can even be referred to as NHT or National Hose Thread but NST or NH is more common these days. NH = NST.

  • The female side of a NH / NST coupling will only connect to a male NH / NST connection
  • The male side of a NH / NST coupling will only connect to a female NH / NST connection

NPSH: National Pipe Straight Hose (NPSH) or Iron Pipe Thread (IPT) has the same threads per inch (TPI) as National Pipe Tapered (NPT) but the thread does not taper. NPSH is a straight thread and seals by a gasket in the female coupling which allows for a swivel, just like NH / NST, which make both ideal for hose couplings.

  • The female side of a NPSH coupling will only connect to a male NPT pipe or a male NPSH connection
  • The male side of a NPSH coupling will only connect to a female NPSH connection
  • It will NOT thread into a female NPT pipe. For example, a male NPSH coupling will NOT thread into a female metal or pvc pipe.

NPT: National Pipe Tapered is common in plumbing and some industrial uses. Sometimes referred to as pipe thread because PVC pipe and schedule 40 pipe are typically threaded in NPT. As its name implies this is a tapered thread so that the outside diameter of the male (ODM) gets smaller towards the end of the fitting and the inside diameter of the female narrows with depth. As the two fittings are threaded together the opposite tapers force thread friction and makes the seal without the use of a gasket.

Warranty Information

Limited 1-Year Warranty

We will replace any fire hose with manufacturer defects in material and workmanship. All warranty claims must be returned to us for inspection before we determine a solution.

Our warranty does not cover gaskets, shipping cost, cosmetic damages, normal wear-and-tear, improper use or chemical damage.

Fire hoses purchased for use at Fire Training Facilities will have a 90-day Manufacturer Defect warranty only.

Upon receipt of the returned goods, hoses will be subject to inspection and testing.

Should it be determined that the hose is covered by warranty, it will be repaired or replaced.